Audiometer Brands for Screening Diagnostic and Channel Selection

Short answer: Try the Interacoustics AS608 or AS608e for basic screening. You can also pick the MAICO MA 25 or MA 25e. The Amplivox Model 116 is another solid choice. These units check air conduction easily.For heavier diagnostic tasks, look at other gear. Check out the QUALMEDI QA700 or QA700 Plus. The Interacoustics AC40 and MAICO MA 42 are also great. You might even prefer the Amplivox Model 270+ or GSI AudioStar Pro. Just ensure the unit meets your specific rules. Always verify the channel layout. Also, confirm local market registration.
For channels, the AS608, MA 25, and Model 116 rely on just one channel. The AC40, MA 42, and AudioStar Pro run as complete two-channel setups. The Model 270+ operates as a 1.5 channel unitThe QA700 and QA700 Plus manuals list Channel 1 for sounds. They strictly reserve Channel 2 for masking. They do not possess two completely equal, separate channels. Therefore, full two-channel bids require extra proof. You must ask your seller for a routing matrix. You also need a full test report.
Certified Brand Evidence at a Glance
Certification answer: The MA 25 datasheet from MAICO lists Type 4 rules and shows CE 0123 Class IIa status. Interacoustics openly shares exact AC40 manuals and specs. QUALMEDI gives specific IFUs, a CFS, and a voluntary VoC. However, their EU access is not fully clear yet. Buyers must wait until the signed EU Declaration of Conformity and its dossier are fully checked.
|
Brand and Model |
Clinical Fit |
Evidence Reviewed |
Procurement Limitation |
|
QUALMEDI QA700 and QA700 Plus |
Type 2 diagnostic per IFU |
We reviewed IFUs v2, CFS 2026YB2249, and a voluntary ICR VoC ICR/VC/HM2606294. |
Request the signed EU DoC. Review the latest ISO 13485 paper, regional rules, and routing proof. |
|
Interacoustics AS608 and AS608e |
One-channel screening |
We looked at the official screening page and published ranges. |
Validate the current registration. Ensure you secure the proper transducers and calibration help. |
|
MAICO MA 25 and MA 25e |
One-channel screening |
Its datasheet cites Type 4, IEC 60601 references, and CE 0123 Class IIa MDR. |
Demand the active EU DoC. Inspect the physical setup. See if the supplier has it in stock. |
|
Amplivox Model 116 |
One-channel screening |
The official page lists Type 4, IEC 60645-1, and IEC 60601 references. |
Check if the declaration remains active. Confirm all registration and calibration guidelines. |
|
Interacoustics AC40 |
Full two-channel diagnostic |
We read the official page and Aug 2024 IFU. It notes Type 1 and IEC 60601 references. |
Review local licenses. Confirm matching transducers and required calibration support. |
|
MAICO MA 42 |
Full two-channel diagnostic |
The official page highlights independent channel mixing. |
Request the latest EU DoC. You must also gather local market proof. |
|
Amplivox Model 270+ |
1.5-channel diagnostic |
The page states Type 3BE or Type 2. Its channel guide confirms 1.5 channel. |
Avoid calling this a full two-channel model. Verify the exact setup and registration. |
|
GSI AudioStar Pro |
True two-channel diagnostic |
The vendor site claims true two-channel operation. |
Inspect the current MDR status. Confirm all local market approvals. |
This evidence status reflects documents checked for this article. It is not a complete regulatory audit. Certifications and registration always depend on the exact model, the setup, and the local market.
Screening vs Diagnostic Audiometers
Screening checks if a person meets a basic hearing level or if they need to see a doctor. Schools, primary care clinics, and mobile programs use this a lot. Workplaces also favor light, portable air-conduction devices for quick checks.
Diagnostic testing looks much deeper to investigate the degree of hearing loss. It also tries to figure out the possible type of loss. For this, you need both air and bone conduction testing. You will also need masking and speech testing in quiet, suitable sound rooms. Just having a "diagnostic" label does not replace a qualified examiner, and you must still calibrate the machine often.
Recommended Brands by Clinical Fit
QUALMEDI QA700 and QA700 Plus
The manuals for the QUALMEDI QA700 call both the QA700 and QA700 Plus Type 2 clinical audiometers . They help doctors find hearing issues. Both models cover 125 Hz to 8 kHz. They test air conduction from -10 to 120 dB HL and bone conduction from -10 to 80 dB HL. They include speech testing, masking, sound field tools, and insert earphones. You can save local files as PDF, PNG, XML, or JSON. The manuals also say they connect to HL7, SQL, and FTP interfaces.
The QA700 Plus gives you more automation. It has Hughson-Westlake rules, built-in word lists, and white noise. You also get special tests like Stenger, SISI, and ABLB. Plus, it can save 100,000 audiograms, while the normal QA700 only saves 6,000. Always confirm the accessories and local registration. Make sure the calibration, interface mapping, and channel routing work for you.
Interacoustics AS608 and AC40
Interacoustics makes the AS608 for easy, portable screening. Their main page says it covers 125 Hz to 8 kHz and hits -10 to 100 dB HL. The AS608e model adds automatic Hughson-Westlake testing and computer connections.
The AC40 is a large, published full two-channel clinical audiometer. It handles air, bone, and speech testing, and it also offers masking and special tests. It even does high-frequency checks up to 20 kHz. The official specs list it as IEC 60645-1 Type 1, and it follows IEC 60601-1 and -1-2 rules.
MAICO MA 25 and MA 42
The MAICO MA 25 is a very light screener that weighs only 980 g. It covers 125 Hz to 8 kHz and -10 to 100 dB HL. A datasheet from November 2021 lists it as IEC 60645-1:2017 Type 4. It also holds CE 0123 Class IIa status under EU MDR rules.
MAICO publishes the MA 42 as a two-channel diagnostic device. It handles air, bone, and speech checks with independent channel mixing. The web page notes that features and market availability can change.
Amplivox Model 116 and Model 270+
The Amplivox Model 116 is a Type 4 screener. It is great for schools, primary care, and mobile testing. The main page says it uses IEC 60645-1 rules, and it lists IEC 60601-1 and IEC 60601-1-2 standards too.
The Model 270+ is a 1.5-channel diagnostic machine, so it is not a full two-channel model. Amplivox calls it Type 3BE or Type 2 based on your setup. It follows the exact same three IEC rules.
GSI AudioStar Pro
GSI publishes the AudioStar Pro as a true two-channel clinical audiometer. It does pure-tone and speech tests on both channels. However, its page includes older EU MDD language. Because of this, you must verify its current MDR status and check local authorization.
One Channel vs Two Channel Audiometers
You should pick a one-channel machine for simple air-conduction screening. This lets you test one ear at a time. The AS608, MA 25, and Model 116 are very good choices for this job.
You need two identical, independent channels for flexible masking and binaural signals. They are also necessary for independent speech-and-noise routing or advanced tests. The AC40, MA 42, and AudioStar Pro fit this strict requirement perfectly. The Model 270+ operates on 1.5 channels. If you want a full two-channel tender, the QA700 and QA700 Plus will require additional routing evidence.

Which Certificates and Standards Matter
The best proof is tied to the exact device. It has to be up-to-date. It also needs to be legal in your target market.
The IEC 60645-1:2017 standard lays down core guidelines for pure-tone and speech audiometers. It sorts these devices based on their signals, daily functions, or main purpose.
Meanwhile, IEC 60601-1 focuses on electrical safety, and IEC 60601-1-2 manages electromagnetic compatibility. Yet, neither standard actually proves if the audiometer performs well in clinical settings.
ISO 13485 looks at a factory's quality system, but it never approves the final product. The checked QUALMEDI files simply lack an updated certificate. Therefore, you must demand the specific certificate number, along with the issuer, scope, site, and exact valid dates.
When buying in the EU, always request a signed EU Declaration of Conformity for your exact model. Verify the CE evidence, classification, and authorized rep details. The European Commission warns that voluntary certificates carry zero legal weight for CE marking.
A Certificate of Free Sale (CFS) makes exporting easier. It helps with registration too. But it does not mean the tool is safe or allowed in your local market.
QUALMEDI holds CFS No. 2026YB2249 for the QA700 and QA700 Plus. It allows exports to Algeria. It started on 15 July 2026 and lasts two years. They also have an ICR VoC No. ICR/VC/HM2606294, running from 25 June 2026 to 24 June 2031. It lists MDR, EN 60601-1, EN 60601-1-2, and test report MTZ20260615001MDR. Yet, the VoC is totally voluntary. It misses full Declaration of Conformity needs. Thus, neither paper provides complete EU MDR authorization.
Final Procurement Recommendation
For basic screening, check the AS608, MA 25, or Model 116. The QA700 fits everyday diagnosis requiring hospital links. Grab the QA700 Plus for extra automation, word lists, special tests, and larger storage. If strict two-channel architecture is completely required, select the AC40, MA 42, or AudioStar Pro. You can use the Model 270+ where 1.5-channel diagnostics are enough.
Require every single supplier to prove their clinical functions and channel routing. You must also ask them to prove market authorization, calibration support, software compatibility, and service against the exact quoted configuration.
Sources and Evidence Reviewed
[1] QUALMEDI QA700 Audiometer User Manual, version 2. They released this document on 24 August 2026. [2] QUALMEDI QA700 Plus Audiometer User Manual, version 2. This dates to 24 August 2026. [3] ICR Verification of Conformity No. ICR/VC/HM2606294. They issued this paper on 25 June 2026. It expires on 24 June 2031 and links to test report MTZ20260615001MDR. [4] Certificate of Free Sale No. 2026YB2249. The China Chamber of Commerce for Import and Export of Medicines and Health Products issued it on 15 July 2026. It allows exports to Algeria and lasts exactly two years. [5] QUALMEDI company website and its active QA700 listing. [6] Interacoustics AS608 main product page. [7] Interacoustics AC40 main product page.[8] Interacoustics AC40 Instructions for Use D-0133688-B. This pairs with technical specification D-0106990-I. Both files date back to August 2024.[9] MAICO MA 25 official product page. Official source (accessed 26 October 2026). [10] MAICO MA 25 datasheet 850 051/12. They released this document in November 2021. [11] MAICO MA 42 official product page. [12] Amplivox Model 116 official product page. [13] Amplivox Model 270+ official product page. [14] Amplivox guide: "What is the difference between a 1.5 and 2-channel audiometer." They posted this on 4 April 2023. [15] Grason-Stadler GSI AudioStar Pro main product page. [16] IEC 60645-1:2017 official publication page. The standard went live on 14 March 2017. [17] ISO 13485:2016 official overview. [18] European Commission UDI Helpdesk. It explains the Declaration of Conformity under MDR 2017/745. [19] Your Europe website. It outlines CE marking requirements. It also warns buyers about voluntary certificates.